‰ NOW 13 WPM ‰ TEXT IS FROM JANUARY 2017 QST PAGE 46 ‰ PROCESS TO CABLE AND NEST EACH OF THE FOUR INNER SECTIONS. MY DESIGN INCLUDED TWO NORMALLY CLOSED MAGNETIC LIMIT SWITCHES AT THE TOP OF THE 3 INCH BOTTOM SECTION, SPACED TO ALLOW EITHER 8 OR 6 INCHES OF TUBING OVERLAP AT MAXIMUM EXTENSION. THERE IS A SINGLE LIMIT SWITCH AT THE BOTTOM OF THE SAME SECTION, AND IF ANY LIMIT SWITCH IS OPENED, POWER TO THE WINCH MOTOR IS INSTANTLY CUT. ITS NOT NECESSARY TO WATCH OTHER SECTIONS BECAUSE ALL MAST SECTIONS MOVE SYNCHRONOUSLY AND ARE THE SAME LENGTH. A FINAL FAIL ƒ QST DE W1AW ‰ SAFE BOLT WAS ALSO INSTALLED TO PREVENT THE SECTIONS FROM ACCIDENTALLY COMING APART EVEN IF THE TOP LIMIT SWITCHES FAIL. A BOTTOM FAIL SAFE IS NOT NEEDED, BECAUSE THE SECTIONS ARE HARD STOPPED WHEN THE PULLEY HOUSINGS NEST TOGETHER. ALL LIMIT SWITCHES AND THE SAFETY BOLT WERE INSTALLED ON A SIDE OF THE TUBING AWAY FROM THE PULLEYS AND CABLE RUNS. I FOUND THAT IN ORDER TO MOUNT THE LIMIT SWITCH MAGNET AND FAIL SAFE BOLT ON THE FIRST ‰ END OF 13 WPM TEXT ‰ QST DE W1AW ƒ